Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 155: 108920, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31622844

RESUMO

The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%. Locating peaks at these relatively high peak-area uncertainties with a probability greater than 0.95 is only possible in the library-driven mode, where the peak positions are supposed a-priori. The deficiencies of the library-driven mode and the possibilities to improve the probabilities of locating peaks are briefly discussed.

2.
Appl Radiat Isot ; 134: 51-55, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28673731

RESUMO

A method is presented for calculating the expected number of counts in peaks that have a large relative peak-area uncertainty and appear in measured gamma-ray spectra. The method was applied to calculations of the correction factors for peaks occurring in the spectra of radon daughters. It was shown that the factors used for correcting the calculated peak areas to their expected values decrease with an increasing relative peak-area uncertainty. The accuracy of taking the systematic influence inducing the correction factors into account is given by the dispersion of the correction factors corresponding to specific peaks. It was shown that the highest accuracy is obtained in the peak analyses with the GammaVision and Gamma-W software.

3.
Appl Radiat Isot ; 87: 73-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24360863

RESUMO

Coal as fossil fuel mainly contains naturally occurring radionuclides from the uranium and thorium series and (40)K. Use of coal, primarily in industry, as a result has dispersion of radioactive material from coal in and through air and water. The aim of this study was to determine the activity concentrations of natural radionuclides in coal samples from open pit mines "Kolubara" and to evaluate its effect on population health. The results showed that all measured and calculated values were below the limits recommended in international legislation.

4.
Appl Radiat Isot ; 70(9): 1860-2, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22405642

RESUMO

In order to assure Quality Control in accordance with ISO/IEC 17025, it was important, from metrological point of view, to examine the long-term stability of calibration standards previously prepared. Comprehensive reconsideration on efficiency curves with respect to the ageing of calibration standards is presented in this paper. The calibration standards were re-used after a period of 5 years and analysis of the results showed discrepancies in efficiency values.


Assuntos
Calibragem/normas , Radioisótopos/análise , Radioisótopos/química , Radiometria/normas , Internacionalidade , Estudos Longitudinais , Doses de Radiação , Padrões de Referência , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...